Allow the motor to cool, ensure the switch is off, and press the reset button on the motor.
Tips for cooler operation:
- Improve ambient conditions
- Improve ambient ventilation/aeration
- Move the compressor to a shaded area
- Eliminate extension cord
An improper extension cord could cause motor shut-off.
If an extension cord must be used, be sure it is:
• a 3-wire extension cord that has a 3-blade grounding plug
and a 3-slot receptacle that will accept the plug on the
product.
• In good condition.
• No longer than 50 feet (15,2 m)
• 12 gauge (AWG) or larger. (Wire size increases as gauge
number decreases. 10 AWG and 8 AWG may also be used.
DO NOT USE 14 OR 16 AWG).
Please see attached document for step-by-step instructions.